Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124

Shandong Shengtai instrument co.,ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124

Packaging Details : wooden case

Electrode material : special steel

Empty cup capacitance : 30.0pF

Model Number : SH124

Test range : 2.0 x 105 ~ 1.0 x 1013 Ω m.

Power : 500 w or less

Payment Terms : T/T

Discharge time : 0 ~ 9 minutes

Insulation material : PTFE

Delivery Time : 7-15work-days

Electrode type : three terminal electrode, internal and external electrode double temperature control

Empty glass insulation resistance : > 3.0 x 1012 Ω

Working environment : temperature 10 ~ 35℃, humidity ≤ 85%

Supply Ability : 100000sets/year

Temperature control range : 15 ~ 100℃, temperature control accuracy ±0.5℃

Power source : AC 220V± 10%, 50Hz± 5%

Place of Origin : China

Constant temperature time : 0 ~ 59 minutes

MOQ : 1

Charging time : 0 ~ 99 seconds

Electrode spacing : 2.0mm

Brand Name : Shengtai Instrument

Executive standard : DL/T421, GB/T5654

Contact Now

SH124 Automatic Volume Resistivity Tester
The SH124 Automatic Volume Resistivity Tester is developed and manufactured in compliance with China’s electric power industry standard DL/T421-2009 and national standard GB/T5654. It is applied to test the volume resistivity of liquid dielectrics including insulating oil and fuel oil.
This instrument adopts an MCS-51 series single-chip microcomputer as the core control unit, equipped with a color LCD screen and Chinese human-machine interactive interface to guide users through operations. The entire measuring process is fully automatic, featuring automatic electrode cup switching and automatic range shifting. It supports cyclic storage of up to 200 groups of test data and integrates cutting-edge modern technological innovations.
With advanced design, rational mechanical layout, easy operation as well as stable and safe performance, this tester delivers top-tier performance metrics among comparable domestic and international counterparts. It serves as an ideal resistivity testing device for oil condition monitoring, and its test results fully meet the requirements specified in DL421-91 for volume resistivity measurement of insulating oil.
Product Aliases
Automatic Transformer Oil Tan Delta & Volume Resistivity Tester
Automatic Volume Resistivity Tester for Fire-Resistant Oil
Self-Cleaning Automatic Volume Resistivity Tester
Automatic Insulating Oil Volume Resistivity Tester

Technical parameters

Executive standard: DL/T421, GB/T5654

Test range: 2.0 x 105 ~ 1.0 x 1013 Ω m.

Test accuracy: repeatability:

Volume resistivity > 1.0 x 1010 Ω m., the relative error of 25%

Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 15%

Reproducibility:

Volume resistivity > 1.0 x 1010 Ω m., the relative error of 35%

Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 25%

Test voltage: 500 VDC maximum error 0.5 %

Constant temperature time: 0 ~ 59 minutes

Charging time: 0 ~ 99 seconds

Discharge time: 0 ~ 9 minutes

Temperature control range: 15 ~ 100℃, temperature control accuracy ±0.5℃

Electrode cup parameters:

Electrode type: three terminal electrode, internal and external electrode double temperature control

Electrode material: special steel

Insulation material: PTFE

Electrode spacing: 2.0mm

Empty cup capacitance: 30.0pF

Empty glass insulation resistance: > 3.0 x 1012 Ω

Power source: AC 220V± 10%, 50Hz± 5%

Power: 500 w or less

Working environment: temperature 10 ~ 35℃, humidity ≤ 85%

SH124 Automatic volume resistivity tester

Executive standard DL/T421, GB/T5654
Test range 2.0 x 105 ~ 1.0 x 1013 Ω m.
Test accuracy: repeatability

Volume resistivity > 1.0 x 1010 Ω m., the relative error of 25%

Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 15%

Reproducibility

Volume resistivity > 1.0 x 1010 Ω m., the relative error of 35%

Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 25%

Test voltage: 500 VDC maximum error 0.5 %

Constant temperature time

0 ~ 59 minutes

Charging time 0 ~ 99 seconds
Discharge time 0 ~ 9 minutes
Temperature control range 15 ~ 100℃, temperature control accuracy ±0.5℃
Electrode type three terminal electrode, internal and external electrode double temperature control
Electrode material

special steel

Insulation material PTFE
Electrode spacing 2.0mm
Empty cup capacitance 30.0pF
Empty glass insulation resistance > 3.0 x 1012 Ω
Power source AC 220V± 10%, 50Hz± 5%
Power 500 w or less
Working environment temperature 10 ~ 35℃, humidity ≤ 85%

Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124

Packing list

S/N Name Quantity Unit Remarks
1 Host 1 set
2 Electrode cup 1 set
3 power cord 1 piece
4 Instructions 1 copy
5 Packing list 1 copy
6 Certificate warranty card 1 copy


Product Tags:

Automatic transformer oil dielectric loss tester

      

Transformer oil volume resistivity test equipment

      

SH124 oil testing equipment with warranty

      
Quality Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124 for sale

Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shandong Shengtai instrument co.,ltd
*Subject:
*Message:
Characters Remaining: (0/3000)